Prenatal Neonatal

Hearing Loss Susceptibility GenoArray Diagnostic Kit

耳聋PCR试剂包装盒

Summary:Rapid and accurate screening of 13 common mutation types of 4 hearing-loss related genes.

Features:

-Detect 4 hearing-loss related genes: GJB2, GJB3, SLC26A4 , 12S rRNA

-Rapid and Convenient. The whole detection process can be accomplished within 3 hours.

-Reliable results with 100% accuracy comparing to sequencing of 1050 cases in China

-Differentiation of Homozygous/Heterozygous carriers

Sample Collection Medium:

Peripheral blood, amniotic fluid, cord blood sample

Specification

Reference code: HBGA-HLS

No. of Tests per kit: 30

Analysis: 13 mutation types of the 4 hearing-loss genes

Sample type: Whole blood, Dried blood spot, or Buccal swab

Device/instrument required: Thermal Cycler and HybriMax®

Sample volume required: 1 ml Whole Blood

Controls: Biotin control

Maximum run at a time: 15 tests (including positive control and negative control)

Result: 13 mutation types in one single test.

Glucose-6-Phosphate Dehydrogenase Deficiency (G6DP Deficiency)

G6PD

Summary: Effective and cost-efficient for detection of 14 common mutation types of the G6PD genes

Features:

– Rapid and accurate. The result can be obtained within 3 hours.

-14 mutations (95、392、487、493、592、871、1004、1024、1311、1360、1376、1381、1387、1388)

– Amplification control (IC) and hybridization control (Biotin) for the monitoring of the entire process

–Differentiation of Homozygous/Heterozygous carriers

Sample collection medium:

-Peripheral blood, amniotic fluid and cord blood sample

Specifications:

Reference code: HBGA-G6DP

No. of Test per kit: 30

Sample Types: Peripheral blood, Amniotic fluid, EDTA whole blood, Dried blood spot

Device/instrument required: Thermal Cycler and HybriMax®

Sample volume required:       1 ml

Controls:      Internal Control (PCR amplification), Biotin (Hybridization)

Maximum run at a time: 15 tests (including positive control and negative control)

Result: 14 common mutation types in a single reaction

Phenylalanine Hydroxylase Deficiency Diagnostic Kit (PKU)

Summary:Effective and cost-efficient for detection of 22 mutation targets on the phenylalanine hydroxylase, PAH gene simultaneously

Features:

– High sensitivity and specificity: >95%

-Low Cost; Detecting the level of Phenylalanine as an indication of PAH mutation

– Rapid and accurate. The result can be obtained within 3 hours

Sample collection medium:

– EDTA Whole Blood, Dried blood spot

Specifications

Reference code: HBGA-PKU

No. of Test per kit: 30

Sample Types: Peripheral blood, Cord blood sample, EDTA Whole Blood, Dried blood spot

Device/instrument required: Thermal Cycler and HybriMax®

Sample volume required:       1 ml

Controls:      Internal Control (PCR amplification), Biotin (Hybridization)

Maximum run at a time: 15 tests (including positive control and negative control)

Result: 22 common mutation types in a single reaction

Y-Chromosome Microdeletion Detection Kit

Summary:Effective and cost-efficient for detection of Y chromosome AZF gene family AZFa, AZFb, AZFc, AZFd four regions of 15 sequence tagged sites (STS) microdeletions,

Features:

– High sensitivity and specificity: >95%

Sample collection medium:

– EDTA Whole Blood, Dried blood spot

Specifications

Reference Code: HBRT-YCM

No. of Test per kit: 30

Sample Types: EDTA Whole Blood

Device/instrument required: Thermal Cycler and HybriMax®

Sample volume required:       1 ml

Controls:      Internal Control (PCR amplification), Biotin (Hybridization)

Maximum run at a time: 24 tests with Internal Control (IC), External Control (Negative)

Result: Detection of 4 mutation regions in a single reaction

Hepatitis B Real-Time PCR Kits

Summary:High sensitivity and Quantitative Detection of all HBV subtypes

Sample collection medium:

EDTA serum or EDTA plasma

Specifications

Reference Code: HBRT-HBV

No. of Test per kit: 48

Sample Types: EDTA serum or EDTA plasma

Device/instrument required: Thermal Cycler and HybriMax®

Sample volume required:       1 ml

Controls:      Internal Control (PCR amplification), Biotin (Hybridization)

Result: Quantitative detection of HBV with all subtypes (A, B, C, D, E, F, G, H) in a single reaction